TM-9-2520-272-40 Direct Support for M113A3 X200-4A Transmission 2520-01-397-1074 Download
Page 92 of 620
TM 9-2520-272-40 0013 REMOVE G2 BACKUP VALVE ASSEMBLY NOTE Top cover assembly is removed from transmission. Wiring harness does not have to be removed to remove G2 backup valve assembly. Transmission is upright on f oor or work table. 1. Disconnect plastic connectors that attach wiring harness to solenoids. 2. Remove two 1/4-18 x 2-1/4 inch bolts (Figure 1, Item 1) and two washers (Figure 1, Item 2) that attach G2 backup valve assembly (Figure 1, item 5) to separator plate (Figure 1, Item 4). 3. Remove two 1/4-18 x 1-3/4 inch bolts (Figure 1, Item 3) and two washers (Figure 1, Item 2) that attach G2 backup valve assembly (Figure 1, item 5) to separator plate (Figure 1, Item 4). 4. Remove G2 backup valve assembly (Figure 1, Item 5). Figure 1. G2 Backup Valve Assembly Removal. END OF TASK 0013‐2