TM-9-2520-272-40 Direct Support for M113A3 X200-4A Transmission 2520-01-397-1074 Download

Page 577 of 620

TM 9-2520-272-40 0072 7. Pry plain encased seal (Figure 2, Item 6) from inside of cover. Discard seal (Figure 2, Item 6). END OF TASK INSTALL PUSH ROD COMPONENTS 1. Using a 1/2 inch drive, 13/16 inch socket as a driver, drive against the identif cation numbers on new plain encased seal (Figure 2, Item 6). 2. Install new plain encased seal (Figure 2, Item 6) to a f rm seat against the shoulder in the bore. Figure 2. Seal. 3. Insert rod (Figure 3, Item 3) through bracket (Figure 3, Item 7). 4. Install extension (Figure 3, Item 5), beveled end f rst, into bore. 5. Tap extension into seal (Figure 3, Item 6) so that pin hole is about 3/8 inch from inside of cover. 6. (Soldier 1) Hold the extension f rmly in place by hand. Be sure to keep holding extension until pin (Figure 4, Item 2) is installed. Figure 3. Push Rod Installation. 00723