TM 9-2520-272-40 0044 3. Look through sump communication tube (Figure 4, Item 3) and make sure that you can see the tube bore in left end of center housing assembly (Figure 4, Item 2). Push small end of tube into left end bore. 4. Tap end of sump communication tube (Figure 4, Item 3) at right end until the small end of tube is installed in left end bore and large end of tube is f ush at right end bore. Figure 4. Sump Communication Tube, Flush at Left End. END OF TASK END OF WORK PACKAGE 0044‐4