TM-9-2520-272-40 Direct Support for M113A3 X200-4A Transmission 2520-01-397-1074 Download
Page 334 of 620
TM 9-2520-272-40 0041 16.Install f ve zinc-plated 3/8-16 x 2-3/4 inch bolts (Figure 10, Item 29) and f ve washers (Figure 10, Item 30) in input housing (Figure 10, Item 3). 17.Install two zinc-plated 3/8-16 x 1-1/4 inch bolts (Figure 10, Item 4) and two washers (Figure 10, Item 5) in input housing (Figure 10, Item 3). Figure 10. Input Housing Hardware Installation, Left Side. 18.Install zinc-plated 3/8-16 x 1-1/4 inch bolt (Figure 11, Item 10) and washer (Figure 11, Item 9) in input housing (Figure 11, Item 3). Figure 11. Hardware Installation, Center. 0041‐8