TM-9-2520-272-40 Direct Support for M113A3 X200-4A Transmission 2520-01-397-1074 Download
Page 299 of 620
TM 9-2520-272-40 0038 INSTALL FILTER TUBES 1. Install new packing (Figure 2, Item 5) on end of jumper tube (Figure 2, Item 6). 2. Apply petrolatum to new packing (Figure 2, Item 5). 3. Install four new packings (Figure 2, Item 2), two packings on f lter-in tube (Figure 2, Item 3) and two packings on f lter-out tube (Figure 2, Item 4). 4. Apply petrolatum to four new packings (Figure 2, Item 2). NOTE The f lter-in tube is 3.60 in. (91.44 mm) long. The f lter-out tube is 2.25 in. (57.15 mm) long. The f lter-out tube (shorter tube) is installed closest to the input housing. 5. Install f lter-out tube (Figure 2, Item 4) in center housing assembly (Figure 2, Item 7), top or bottom end of tube in f rst. 6. Install f lter-in tube (Figure 2, Item 3) in center housing assembly (Figure 2, Item 7), top or bottom end of tube in f rst. Figure 2. Filter Tubes and Packings Installation. END OF TASK 0038‐3