TM-9-2520-254-34 Direct Support for M113 TX100-1 Transmission 2520-00-066-4240 Download

Page 113 of 126

Figure 5-144. Figure 142. Figure 5-143. (2) The 0-400 psi gage, hose, and fittings from oil gage kit 4910-572-8612, and the method of attaching are shown in figure 5-143. (3) The 0-100 psi gage, hose, and fittings from oil gage kit 4910-5’72-8612, and the method of attaching are shown in figure 5-144. (4) The tapped holes in the transmission housing, to which the oil cooler lines connect, are shown in figure 5-145. Oil temperature, converter- out pressure, and lubrication pressure may be measured by installing suitable fittings, and connecting gages to the lines which attach at these openings. (5) When connecting gages into lines attached to the openings shown in figure 5-145, the con- verter-out pressure and temperature gages both must be connected into the oil line which attaches at the rear opening. The lubrication pressure may be taken at the line which attaches at the forward opening. 5-63