30. Reverse housing assembly (Figure 26, Item 11). 31. Install fan pulley (Figure 26, Item 8) on housing assembly (Figure 26, Item 11). Secure pulley with six screws (Figure 26, Item 9) and six washers (Figure 26, Item 10). Torque screws (Figure 26, Item 9) to 210-220 lb-in (24-25 N·m). Use torque wrench (WP 0069, Item 38). Figure 26. Fan Pulley – Installation. 32. Lubricate new preformed packing (Figure 27, Item 6) and install on generator pulley (Figure 27, Item 3). 33. Install key (Figure 27, Item 7) on shaft (Figure 27, Item 29). 34. Install generator pulley (Figure 27, Item 3) on fan pulley (Figure 27, Item 8). Secure with screw (Figure 27, Item 1) and washer (Figure 27, Item 2). Torque screw (Figure 27, Item 1) to 76-79 lb-ft (103-108 N·m). Use torque wrench (WP 0069, Item 42). Figure 27. Generator Pulley – Installation. FOLLOW ON MAINTENANCE 1. Return to supply per local Standard Operating Procedures (SOP). END OF TASK END OF WORK PACKAGE TM 9-2350-277-40&P 0007 0007‐15/16 blank