3. Install three jacking screws (Figure 2, Item 5) in generator pulley (Figure 2, Item 3). Figure 2. Jack Screws – Installation. 4. Using three jacking screws (Figure 3, Item 5), separate generator pulley (Figure 3, Item 3) from fan pulley (Figure 3, Item 8). Remove preformed packing (Figure 3, Item 6) and key (Figure 3, Item 7). Discard preformed packing. 5. Secure fan pulley (Figure 3, Item 8) in holding fixture. Figure 3. Generator Pulley – Removal. TM 9-2350-277-40&P 0007 00072