TM-9-2350-277-40&P Sustainment Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 57 of 472

SUSTAINMENT MAINTENANCE REPAIR RADIATOR INITIAL SETUP: Tools and Special Tools Apron (WP 0069, Item 1) Brush, Wire, Scratch (WP 0069, Item 3) Industrial Goggles (WP 0069, Item 6) Radiator Test Plug Set (WP 0069, Item 16) Radiator Test Stand (WP 0069, Item 25) Shop Equipment, Radiator (WP 0069, Item 22A) Soldering Torch Kit (WP 0069, Item 23A) Materials/Parts Soldering flux (WP 0068, Item 16) Tin alloy solder (WP 0068, Item 17) Personnel Required Allied Trade Specialist 91E10 References TM 750-254 Equipment Condition Radiator removed from carrier (TM 9-2350-277-13&P) WARNING Air pressure in excess of 30 psi (207 kPa) can injure personnel. Do not direct pressurized air at yourself or others. Always wear goggles. TESTING RADIATOR FOR FLOW 1. Plug auxiliary tank connector opening (Figure 1, Item 1). Use radiator test plug set. 2. Plug radiator outlet opening (Figure 1, Item 3). Use radiator test plug set. 3. Immerse radiator in water. Direct air at 25-30 psi (172-207 kPa) into inlet opening (Figure 1, Item 2). Use a suitable water container. 4. If air bubbles appear, repair radiator. Figure 1. Radiator Testing. TM 9-2350-277-40&P 0006 00061 CHANGE 1