TM-9-2350-277-40&P Sustainment Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 231 of 472
ASSEMBLY NOTE Use Wiring Diagrams Figure 3, page 0034-4 for installation of wires to connectors. 1. Install four connectors (Figure 2, Item 9), dust caps (Figure 2, Item 8), on cover (Figure 2, Item 5). Secure with 16 screws (Figure 2, Item 7) and new locknuts (Figure 2, Item 4). 2. Install connector J1 (Figure 2, Item 2) on extension box (Figure 2, Item 1). Secure with four screws (Figure 2, Item 10) and new locknuts (Figure 2, Item 3). NOTE Color Designation for Terminals: H (HOT) = YELLOW , N (NEUTRAL) = WHITE , G (GROUND) = GREEN 3. Connect leads to connectors if necessary. 4. Install cover (Figure 2, Item 5) with gasket on extension box (Figure 2, Item 1) and secure with four screws (Figure 2, Item 6). Figure 2. AC Power Extension Box – Assembly. TM 9-2350-277-40&P 0034 0034‐3 CHANGE 1