TM-9-2350-277-40&P Sustainment Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 216 of 472
5. Remove seven screws (Figure , Item 19), seven speed nuts (Figure , Item 16), and cover (Figure , Item 10) from blower plate (Figure , Item 12). 6. Loosen set screw (Figure , Item 18) and remove fan vane (Figure , Item 11) from motor (Figure , Item 14). 7. Remove three screws (Figure 2, Item 17), three spacers (Figure 2, Item 15), grommets (Figure 2, Item 13), and motor (Figure 2, Item 14) from blower plate (Figure 2, Item 12). END OF TASK INSTALLATION 1. Install motor (Figure 2, Item 14) in blower plate (Figure 2, Item 12). Secure with three screws (Figure 2, Item 17), three spacers (Figure 2, Item 15), and grommets (Figure 2, Item 13). 2. Place fan vane (Figure 2, Item 11) flush with end of motor shaft. Secure with set screw (Figure 2, Item 18). 3. Install cover (Figure 2, Item 10) on blower plate (Figure 2, Item 12). Secure with seven screws (Figure 2, Item 19) and seven speed nuts (Figure 2, Item 16). Turn fan vane (Figure 2, Item 11) through combustion tube opening to make sure fan vane is clear. Figure 2. Blower Motor – Disassembly, Assembly. TM 9-2350-277-40&P 0032 0032‐2