TM-9-2350-277-40&P Sustainment Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 199 of 472

3. Install blower assembly (Figure 4, Item 5) on heater (Figure 4, Item 3) and turn clockwise. Secure with four nuts (Figure 4, Item 4). 4. Connect blower assembly lead (Figure 4, Item 6) to terminal number six of terminal strap (Figure 4, Item 7). 5. Place combustion tube assembly (Figure 4, Item 8) on coolant heater (Figure 4, Item 3) and blower assembly (Figure 4, Item 5). Secure with nut (Figure 4, Item 9). 6. Install guard (Figure 4, Item 1) on coolant heater (Figure 4, Item 3). Secure with four screws (Figure 4, Item 2). Figure 4. Combustion Tube and Blower Assembly – Installation. FOLLOW ON MAINTENANCE 1. Return to supply per local Standard Operating Procedures (SOP). END OF TASK END OF WORK PACKAGE TM 9-2350-277-40&P 0027 00273/4 blank