TM-9-2350-277-40&P Sustainment Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 167 of 472
51. Remove batteries and retainers. See TM 9-2350-277-13&P. 52. Clean battery box with cleaning compound. 53. Renew adhesive backing on insulation sheets with cleaning compound. Wait 10 to 20 seconds until adhesive becomes tacky. 54. Install insulation sheets (Figure 11, Item 85), (Figure 11, Item 86), (Figure 11, Item 84), and (Figure 11, Item 83) and strip (Figure 11, Item 81) in battery box (Figure 11, Item 82). 55. Install insulation sheets (Figure 11, Item 80) on battery box covers (Figure 11, Item 79). Figure 11. Battery Insulation Sheet – Installation. TM 9-2350-277-40&P 0024 0024‐11