TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 96 of 820
TM 9-2350-277-34 PATCH PANEL BOX A10 INOPERATIVE (M1068A3 ONLY)—Continued 0010 00 GY 1. Remove cable plugs from the Patch Panel Box A10 jacks as follows: Cable W111 plug P1 (1) from J125 (5) Cable W112 plug P1 (2) from J124 (8) Cable W113 plug P1 (3) from J123 (7) Cable W114 plug P1 (4) from J126 (6) 2. Measure resistance between pins of the following: J125 (5) to J119 (9) J126 (6) to J120 (10) J123 (7) to J121 (11) J124 (8) to J122 (12) 3. Does multimeter read 0 ohms for each measurement? YES NO GYN 1. Repair Patch Panel Box A10 (WP 0099 00). 2. Verify no faults found. 0010 00-14