TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 94 of 820
TM 9-2350-277-34 PATCH PANEL BOX A10 INOPERATIVE (M1068A3 ONLY)—Continued 0010 00 F2Y 1. Measure resistance between pins (P1 thru P52) on plug P105 (1) of cable W118 and pins (p1 A or B thru p26 A or B) on connector J101 (2) of External Communication Box A11 (3) front panel as follows: P1 to p1A P2 to p1B P3 to p2A P4 to p2B P5 to p3A P6 to p3B P7 to p4A P8 to p4B P9 to p5A P10 to p5B P11 to p6A P12 to p6B P13 to p7A P14 to p7B P15 to p8A P16 to p8B P17 to p9A P18 to p9B P19 to p10A P20 to p10B P21 to p11A P22 to p11B P23 to p12A P24 to p12B P25 to p13A P26 to p13B P27 to p14A P28 to p14B P29 to p15A P30 to p15B P31 to p16A P32 to p16B P33 to p17A P34 to p17B P35 to p18A P36 to p18B P37 to p19A P38 to p19B P39 to p20A P40 to p20B P41 to p21A P42 to p21B P43 to p22A P44 to p22B P45 to p23A P46 to p23B P47 to p24A P48 to p24B P49 to p25A P50 to p25B P51 to p26A P52 to p26B 2. Does multimeter read 0 ohms for each measurement? YES NO F2YN 1. Replace cable W118 (WP 0108 00). 2. Verify no faults found. 0010 00-12