TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 86 of 820

TM 9-2350-277-34 PATCH PANEL BOX A10 INOPERATIVE (M1068A3 ONLY)—Continued 0010 00 B2Y 1. Measure resistance between pins on cable W115 plug P106 (1) and posts on External Communication Box A11 (2) front panel as follows: Post 1 (Blk) to pin A Post 1 (Red) to pin B Post 2 (Blk) to pin C Post 2 (Red) to pin D Post 3 (Blk) to pin E Post 3 (Red) to pin F Post 4 (Blk) to pin G Post 4 (Red) to pin H Post 5 (Blk) to pin J Post 5 (Red) to pin K Post 6 (Blk) to pin L Post 6 (Red) to pin M Post 7 (Blk) to pin N Post 7 (Red) to pin P Post 8 (Blk) to pin R Post 8 (Red) to pin S 2. Does multimeter read 0 ohms for each measurement? YES NO B2YN 1. Replace cable W115 (WP 0107 00). 2. Verify no faults found. B3Y 1. Verify no faults found. 0010 00-4