TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 84 of 820

TM 9-2350-277-34 PATCH PANEL BOX A10 INOPERATIVE (M1068A3 ONLY)—Continued 0010 00 2Y 1. Is there output from CURBSIDE DATA PANEL sockets? YES NO GO TO DY (PAGE 0010 00-7) 3Y 1. Is there output from ROADSIDE DATA PANEL sockets? YES NO GO TO EY (PAGE 0010 00-9) 4Y 1. Is there output from EXTERNAL COMM CABLE HOCK sockets? YES NO GO TO FY (PAGE 0010 00-11) 5Y 1. Is there output from RF jacks J119, J120, J121, and/or J122? YES NO GO TO GY (PAGE 0010 00-14) 6Y 1. Verify no faults found. 0010 00-2