TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 75 of 820

TM 9-2350-277-34 NO DC OUTPUT FROM DC POWER SUPPLY (M1068A3 ONLY) 0009 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Direct Support T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0120 00, Item 62) Digital Multimeter (WP 0120 00, Item 38) Special Purpose Power Cable (WP 0121 00, Figure 0121 00-3) P e r s o n n e l R e q u i r e d Power-Generation Equipment Repairer 52D10 Helper (H) R e f e r e n c e s See your -10 See your -20 TM 11-7010-256-12&P See M1068A3 wiring diagram (see your -20) E q u i p m e n t C o n d i t i o n Power control enclosure removed (see your -20) Power control enclosure faceplate lowered and power supply cover removed (see your -20) Unit level troubleshooting completed (see your -20) WARNING HIGH VOLTAGE is used in operation of this equipment. DEATH ON CONTACT may result if personnel fail to observe safety precautions. NEVER work on equipment unless at least one other person familiar with operation and hazards of equipment is nearby. That person should also be familiar with giving first aid. When an operator helps a mechanic, that operator must be warned about dangerous areas. SHUT OFF POWER supply to equipment before beginning work. Make sure all external power is OFF/disconnected. BE CAREFUL not to touch high-voltage connections when installing or operating this equipment. 0009 00-1