TM 9-2350-277-34 REPAIR POWER CONTROL ENCLOSURE, RIGHT PANEL (M1068A3 ONLY) — Continued 0092 00 ASSEMBLY 1. Install two terminal blocks (6), four screws (7), new locknuts (8), and eight washers (9) on enclosure (5). Use wiring diagram. Install all wiring to terminal blocks and secure all set screws. 2. Install ground fault interrupter (2) on enclosure (5) with two new lockwashers (4) and screws (3). Install circuit leads 22A, 21A, 3AA, 18C, and 27A (1) on ground fault interrupter (2). 0092 00-6