TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 612 of 820
TM 9-2350-277-34 REPAIR POWER CONTROL ENCLOSURE, LEFT PANEL (M1068A3 ONLY) — Continued 0091 00 NOTE See wiring diagram for disassembly/assembly of wires/leads. 5. Solder/install four wires (1) on terminals (2) of relay XK4 (3). 6. Install relay XK4 (3) on left panel (4), secure with two screws (5), new locknuts (6), and washers (7). 7. Solder/install five wires (1) on terminals (2) of relay XK3 (8). 8. Install relay XK3 (8) on left panel (4), secure with two screws (5), new locknuts (6), and washers (7). 9. Solder/install four wires (1) on terminals (2) of relay XK5 (9). 10. Install relay XK5 (9) on left panel (4), secure with two screws (5), new locknuts (6), and washers (7). 11. Install eight circuit leads (10) on terminals of relay socket (11), secure with six screws (12) and lockwashers (13). 0091 00-6