TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 609 of 820
TM 9-2350-277-34 REPAIR POWER CONTROL ENCLOSURE, LEFT PANEL (M1068A3 ONLY) — Continued 0091 00 NOTE Tag all leads/wires before removal for proper installation later. See wiring diagram for disassembly/assembly of wires/leads. 5. Remove six screws (12), lockwashers (13), and eight circuit leads (10) from terminals of relay XK2 socket (11). 6. Remove two screws (5), locknuts (6), washers (7), and relay XK5 (9) from left panel (4). Discard locknuts. 7. De-solder/remove four wires (1) from terminals (2) of relay XK5 (9). 8. Remove two screws (5), locknuts (6), washers (7), and relay XK3 (8) from left panel (4). Discard locknuts. 9. De-solder/remove five wires (1) from terminals (2) of relay XK3 (8). 10. Remove two screws (5), locknuts (6), washers (7), and relay XK4 (3) from left panel (4). Discard locknuts. 11. De-solder/remove four wires (1) from terminals (2) of relay XK4 (3). 0091 00-3