TM 9-2350-277-34 REPLACE POWER CONTROL ENCLOSURE POWER SUPPLIES (M1068A3 ONLY) — Continued 0090 00 NOTE Tag all leads before disconnecting rfom terminals. 4. Remove four nuts (1) and five leads (2) from two power supplies (3) and (4). 5. Disconnect jumper cable (5) from two power supplies (3) and (4). 6. Remove three screws (6) and four leads (7) from power supply (3). Lift power supply (3) from enclosure, have helper assist. 7. Remove three screws (8) and five leads (9) from power supply (4). Lift power supply from enclosure, have helper assist. 8. Remove four screws (10), lockwashers (11), and bracket (12) from four isolators (13). Discard lockwashers. 9. Remove 16 locknuts (14), screws (15), and four isolators (13) from enclosure (16). Discard locknuts. 0090 00-3