TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 581 of 820

TM 9-2350-277-34 INSTALL CAPSTAN KIT (M1059A3 ONLY) — Continued 0086 00 12. Weld supports (1) and (2) to top plate of carrier as marked in Step 10 in accordance with TM 9-237. Use electrode type 5356. 13. Clean weld area and apply touch-up paint to repaired area (see TM 43-0139). 14. Unscrew two retainers (3) to remove two drums (4) from two adapters (5). 15. Place one drum (4) over stowage support (1). Place the other drum (4) over stowage support (2). Secure with two retainers (3). Change 3 0086 00-3 8. Make sure retainer (5) is installed in drum (6) with pin (7). 9. Install drum (6) on adapter (3). Secure with retainer (5). 10. Measure and mark the correct positions for the smaller stowage support (1) and for the larger support (2) on top of carrier. NOTE All weld sizes are minimum. Do not exceed 1/16 inch (2 mm) over specified sizes. 11. Remove all paint, anodize, and debris from surfaces under stowage supports to be welded.