TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 553 of 820

TM 9-2350-277-34 REPLACE FUEL CONTROL VALVE — Continued 0078 00 LEAK TEST 1. Repeat high heat fuel flow test. Disconnect both solenoid leads from 24 V dc power source. 2. One or two drops of fuel may form after solenoid leads are disconnected from power source. Further leakage is not acceptable. 3. Replace fuel control valve that leaks. INSTALLATION 1. Connect fuel control valve lead (13) to terminal strap (14). 2. Connect two fuel control valve leads (10) and (11) to overheat thermostat (12). 0078 00-5