TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 55 of 820
TM 9-2350-277-34 VEHICLE WILL NOT ACCEPT EXTERNAL AC POWER (M1068A3 ONLY) 0008 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Direct Support T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0120 00, Item 62) Digital Multimeter (WP 0120 00, Item 38) P e r s o n n e l R e q u i r e d Power-Generation Equipment Repairer 52D10 Helper (H) R e f e r e n c e s See your -10 See your -20 TM 11-7010-256-12&P M1068A3 wiring diagrams (see your -20) E q u i p m e n t C o n d i t i o n Power control enclosure removed (see your -20) Unit level troubleshooting completed (see your -20) WARNING HIGH VOLTAGE is used in the operation of this equipment. DEATH ON CONTACT may result if personnel fail to observe safety precautions. NEVER work on equipment unless at least one other person familiar with the operation and hazards of the equipment is nearby. That person should also be familiar with giving first aid. When an operator helps a mechanic, that operator must be warned about dangerous areas. SHUT OFF POWER supply to equipment before beginning work. Make sure all external power is off/disconnected. BE CAREFUL not to contact high-voltage connections when installing or operating this equipment. 0008 00-1