TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 497 of 820

TM 9-2350-277-34 INSTALL PERSONNEL HEATER KIT (M1064A3 ONLY) — Continued 0073 00 8. Secure plenum (1) to personnel heater (2) with four lockwashers (3) and screws (4). 9. Secure two saddles (5) to two brackets (6) with four screws (7), two lockwashers (8), ground strap (9), and four locknuts (10). 10. Install two clamps (11) on two saddles (5). 0073 00-3 Change 3 11. Install clamp (12) on heater air intake pipe (13) and clamp (14) on heater exhaust port (15). 12. Install elbow (16) on heater air intake pipe (13) and air intake elbow (17). 13. Position heater (2) and shield (18) on two saddles (5), and secure with two clamps (11). Ensure air intake and exhaust fittings are properly aligned. 14. Tighten clamp (14) on heater exhaust port (15) and exhaust pipe in carrier. 15. Tighten clamp (12) on heater air intake pipe (13).