TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 481 of 820
TM 9-2350-277-34 INSTALL PERSONNEL HEATER KIT (M113A3, M1059A3, AND M58 ONLY) — Continued 0072 00 25. Secure fuel pump (1) to threaded bracket (2) with four lockwashers (3), two flat washers (4), and screws (5). NOTE Shielded lead must be secured to weldnut to ensure proper grounding and operation of fuel pump. 26. Secure shielded lead (6) to weldnut (7) with washer (8), two lockwashers (9), and screw (10). 0072 00-7 Change 3