TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 258 of 820
TM 9-2350-277-34 REPLACE FRONT MAIN WIRING HARNESS — Continued 0030 00 35. Install circuits 2 (14), and 2A (20) leads into master switch panel (10) through distribution box (11). Secure circuit 6 (15), 2 (14) and 400 (16) on conductor bus (17) with new locknut (12), and screw (13). Secure circuit 2A (20) lead on conductor bus (17) with lockwasher (19) and nut (18). 36. Install master switch panel (10) on distribution box (11) with eight screws (9), washers (8), and new locknuts (7). 0030 00-30 Change 1