TM-9-2350-277-34 Direct and General Maintenance Manual M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 219 of 820

TM 9-2350-277-34 REPAIR MULTIPIN CONNECTORS — Continued 0026 00 INSTALL CABLE CONNECTOR NOTE If replacing lead, cut new wire from bulk supply. Measure original length, gauge, and type of wire. 1. Strip insulation from leads of cable (3) to uncover just enough wire to fill well in contact (5). 2. Slide retaining nut (1) and coupling nut (6) on cable (3). 3. Push leads of cable (3) through grommet (4) and insert in new contacts (5). NOTE Make sure leads pass through proper lettered hole in grommet. 4. Solder leads in contacts (5) and press contacts into grommet (4). Check leads for resistance. 5. Align and install grommet (4) in plug (2). Secure with retaining nut (1). END OF TASK 0026 00-3/4 blank