TM-9-2350-277-20-6 Unit Maintenance Manual Volume 6 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 85 of 722
TM 9-2350-277-20-6 REPLACE POWER CONTROL ENCLOSURE CIRCUIT 44A LEAD (M1068A3 ONLY) — Continued 0829 00 INSTALLATION 1. Install connector J28 (1) with lead 44A (2) in power control enclosure (3). Secure connector to right panel with four screws (4) and new locknuts (5). 2. Connect cable plug W38P7 (6) to power Control enclosure jack J28 (1). 3. Install lead 44A (2) on terminal X1 of relay K6 (7) and secure with retained lockwasher (8) and nut (9). 4. Secure lead 44A (2) to other leads with new straps (10) as required. 5. Raise faceplate (11) and secure to power control enclosure (3) with 10 new lockwashers (12) and screws (13). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0338 00). END OF TASK 0829 00-3/4 blank