TM-9-2350-277-20-6 Unit Maintenance Manual Volume 6 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 74 of 722

TM 9-2350-277-20-6 REPAIR POWER CONTROL ENCLOSURE FACEPLATE AND BRACKET (M1068A3 ONLY) — Continued 0828 00 11. Remove circuit 31B lead (15) from terminal 1 of circuit breaker CB2 (14). 12. Remove circuit 36C lead (16) from terminal 2 of circuit breaker CB2 (14). 13. Remove four screws (17), lockwashers (18), and circuit breaker CB2 (14) from faceplate (11). Discard lockwashers. 14. Remove four screws (19), locknuts (20), and cascade remote harness RP1 (21) from faceplate (11) and two inverters. Discard locknuts. 0828 00-4