TM-9-2350-277-20-6 Unit Maintenance Manual Volume 6 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 65 of 722
TM 9-2350-277-20-6 REPLACE POWER CONTROL ENCLOSURE AC AND DC METERS AND LIGHT INDICATORS (M1068A3 ONLY) 0827 00 THIS WORK PACKAGE COVERS: Removal (page 0827 00-1). Installation (page 0827 00-4). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0926 00, Item 65) M a t e r i a l s / P a r t s Primer (WP 0928 00, Item 45) Sealing Compound (WP 0928 00, Item 48) Locknut (6) Lockwasher (10) P e r s o n n e l R e q u i r e d Power-Generation Equipment Repairer 52D10 R e f e r e n c e s See your -10 TM 11-7010-256-12&P E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) All external power disconnected (TM 11-7010-256-12&P) Battery ground lead disconnected (WP 0338 00) REMOVAL 1. Remove ten screws (1), lockwashers (2), and lower faceplate assembly (3) from power enclosure (4). Discard lockwashers. 2. Remove nut (5) and safety cover (6) from terminal 2 on meter M1 (7). Unwrap velcro strap (8) from around local wiring. 0827 00-1