TM 9-2350-277-20-6 REPLACE POWER CONTROL ENCLOSURE ASSEMBLY A1 (M1068A3 ONLY) — Continued 0826 00 INSTALLATION 1. Install power control enclosure (1) on inverter housing (2). Secure with eight washers (3) and screws (4). Have helper assist. 2. Connect all cables/connectors (5) to left/right sides of power control enclosure (1). 3. Install bracket (6) on power control enclosure (1). Secure with two new lockwashers (7) and screws (8). FOLLOW-THROUGH STEPS 1. Install cascade remote harness W15 (WP 0847 00). 2. Install roadside data panel A13 (WP 0835 00). 3. Connect battery ground lead (WP 0338 00). END OF TASK 0826 00-3/4 blank