TM-9-2350-277-20-6 Unit Maintenance Manual Volume 6 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 431 of 722

TM 9-2350-277-20-6 REPAIR CHEMICAL ALARM JUNCTION BOX (M113A3 ONLY) 0920 00 THIS WORK PACKAGE COVERS: Removal (page 0920 00-1). Installation (page 0920 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit WP 0926 00, Item 65 M a t e r i a l s / P a r t s Grommet Locknut (3) Locknut (4) P e r s o n n e l R e q u i r e d Unit Mechanic E q u i p m e n t C o n d i t i o n Junction box removed (WP 0919 00) REMOVAL 1. Remove screw (1) and lead (2) from circuit breaker (3). 2. Remove two screws (4), locknuts (5), and circuit breaker (3) from junction box (6). Discard locknuts. NOTE Tag all leads before disconnecting. 3. Remove three screws (7) and three leads (8) from terminal board (9). 0920 00-1