TM-9-2350-277-20-6 Unit Maintenance Manual Volume 6 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 429 of 722
TM 9-2350-277-20-6 REPLACE CHEMICAL ALARM JUNCTION BOX/POWER CABLE/ALARM CABLE (M113A3 ONLY) — Continued 0919 00 7. Connect wiring harness (22) plug (23) to jack on bottom of junction box (5). 8. Connect power cable (9) plug 6B POS (24) to socket (25). 9. Install new lockwasher (26), capacitor bracket (27), two ground leads (28), power cable (9), ground lead (29), clamp (30) with cable (31), new lockwasher (32) and screw (33) on weldnut (34). 0919 00-9 Change 1