TM-9-2350-277-20-6 Unit Maintenance Manual Volume 6 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 405 of 722
TM 9-2350-277-20-6 REMOVE/INSTALL NBC CABLE ASSEMBLY (M58 ONLY) — Continued 0917 00 INSTALLATION NOTE Apply corrosion preventive compound to all threaded fasteners. 1. Install cable assembly (1) on air purifier (2). 2. Loosen screw (3) on right angle connector (4) on cable assembly (1). Slide slotted end of ground wire (5) under screw (3). Tighten screw. 3. Route cable assembly (1) through clamps (6). 4. Install cable assembly (1) on switch (7). 5. Align clamps (6) with weld nuts (8) on bulkhead (9). Secure with new lockwashers (10) and screws (11). FOLLOW-THROUGH STEPS 1. Start engine (see your -10). 2. Raise and lock ramp (see your -10). 3. Stop engine (see your -10). END OF TASK 0917 00-3/4 blank