TM 9-2350-277-20-6 REPLACE/REPAIR INVERTER AC CABLE (W5) (M1068A3 ONLY) — Continued 0839 00 INSTALLATION 1. Install new or repaired harness W5 in carrier. Route terminal ends (1) of W5 through back of inverter housing A2 (2) to the front for connection. 2. Install five terminal leads E1 through E5 (1) of W5 to inverter terminal block TB2 (3) with five screws (4). 3. Attach face plate (5) to front of inverter housing A2 (1) using 10 screws (6) and new lockwashers (7). 4. Connect cable W5 P6 (8) to power control box A1 jack J27 (9). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0338 00). 2. Turn MASTER SWITCH ON (see your -10). Check that electrical system works properly. 3. Turn MASTER SWITCH OFF (see your -10). END OF TASK 0839 00-3/4 blank