TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 92 of 928

TM 9-2350-277-20-5 REPLACE RAMP HYDRAULIC PUMP — Continued 0655 00 REMOVAL WARNING Hydraulic fluid is poisonous and can be absorbed through your skin. Wash off any hydraulic fluid that contacts your skin. Read the hydraulic fluid warning in the front of this manual. 1. Disconnect three hoses (1) from hydraulic pump (2). 2. Remove two screws (3), washers (4), hydraulic pump (2), and gasket (5) from engine. Use universal socket on inboard screw and crow foot attachment on outboard screw. Discard gasket. 3. Remove three elbows (6) and preformed packings (7) from pump (2). Discard packings. 0655 00-2