TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 799 of 928
TM 9-2350-277-20-5 REPLACE WATER/RATION HEATER POWER CABLE (M113A3 ONLY) — Continued 0810 00 6. Reinstall clamp (1), capacitor (2), radio ground lead (3), radio ground lead (4), heater power cable ground lead (7), washer (6), and screw (5) on weldnut (8). 7. Connect heater power cable (5) to cable (1). Secure heater power cable (5) to adjacent wiring harness with new strap (7). 8. Connect heater power cable (5) to water ration heater (6). FOLLOW-THROUGH STEPS 1. Install master switch panel (WP 0260 00). 2. Connect battery ground strap (WP 0337 00). END OF TASK 0810 00-5/6 blank