TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 783 of 928
TM 9--2350--277--20--5 REPL ACE NBC HEAT ER WIRING HARNESS ( M 577A3 O NLY) - Co n t in u e d 0808 00 12. Conne c t wi ri ng ha rne ss (5) t o c ont rol box (7). 13. Install ground lead (10) onto control box (7) with two new lockwashers (9) and screw (8). 14. Inst a l l four sc re ws (1), ne w l oc kwa she rs (2), four c l a m ps (3), and straps (4) on we l dnut s with wiring harness (5) and cable 11. Inst a l l ground l e a d (15 ), l oc kwa she r (12 ), washer (13), a nd sc re w (11 ), and new locknut (14) on frame (16). 10. Install new st raps (17) al ong ground lead (15) and adjacent wiring harness (5). FOLLOW--THROUGH STEPS 1. Master switch panel assembly installed (WP 0261 007). 2. Connect battery ground lead (WP 0338 00). END OF TASK Change 2 0808 00 -- 5/6 blank 8. Connect cable connector (20) onto air purifier (18). 9. Remove screw (19) on air purifier (18). Install ground lead (15) with screw (19) on air purifier (18). NOTE Le ad (15) may be mounted to either front or back side of frame (16).