TM 9--2350--277--20--5 0786 00 --13/14 blank REPLACE NBC FILTERS AND HOSES (M577A3 ONLY) - Continued 0786 00 31. Install hose (1) on filter (2) and tube (3) and tighten two clamps (4). 32. Install hose (5) on filter (6) and tube (7) and tighten two clamps (8). 33. If bracket (9) was removed, install on frame (10). Secure with two screws (11), two new lockwashers (12), two washers (13), and two nuts (14). 34. Secure hoses (1) and (5) to bracket (9) with two clamps (15), screws (16), new lockwashers (17), washers (19). 35. Install hose (20) on precleaner (21) and tube (3) and secure with two clamps (22). 36. Install hose (23) on precleaner (21) and tube (7) and secure with two clamps (24). FOLLOW--THROUGH STEPS 1. Check air flow of NBC system. Follow procedures of TM 3-6680-316-10. Change 2 END OF TASK