TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 595 of 928
TM 9-2350-277-20-5 REPLACE SMOKE GENERATOR GLOW PLUG CABLE ASSEMBLIES (M1059A3 ONLY) — Continued 0772 00 NOTE There are seven clamps that bolt interior cable to hull. One is used on the right side of vehicle and six on the left. All are installed the same way. Only one clamp is shown. Install as required. 7. Install interior cable (1), six clamps (9), screws (10), and new lockwashers (11) to hull. 8. Install interior cable (1), clamp (9), screw (10), and new lockwasher (11) to hull. 9. Connect interior cable (1) to jack 1J6 (12) on back of control panel (13). FOLLOW-THROUGH STEPS 1. Install smoke generator assembly on bracket (WP 0755 00). 2. Install in-board armor shield (WP 0771 00). 3. Connect battery ground strap (WP 0337 00). 4. Set circuit breaker CB1 to ON (TM 3-1040-283-10). END OF TASK 0772 00-5/6 blank