TM 9-2350-277-20-5 REPLACE SMOKE GENERATOR GLOW PLUG CABLE ASSEMBLIES (M1059A3 ONLY) — Continued 0772 00 INSTALLATION NOTE There are two exterior cables, access plates, and smoke generators, left and right. Cables are installed on vehicle the same way. Only one exterior cable, access plate, and smoke generator is shown. Remove cables as required. 1. Install interior cable (1), four screws (2) and new locknuts (3) to right access plate (4). 2. Connect exterior cable (5) to preheat harness jack (6) on panel (7) of right smoke generator (8). 3. Connect exterior cable (5) to interior cable (1) in right access plate (4). 4. Install interior cable (1), four screws (2) and new locknuts (3) to left access plate (4). 5. Connect exterior cable (5) to interior cable (1) in left access plate (4). 6. Connect exterior cable (5) to preheat harness jack (6) on panel (7) of left smoke generator (8). 0772 00-4