TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 551 of 928

TM 9-2350-277-20-5 REPLACE ADAPTER ACCESS PLATE TO GENERATOR ELECTRICAL CABLE ASSEMBLY (M1059A3 ONLY) — Continued 0761 00 INSTALLATION 1. Connect cable assembly (1) to smoke generator cover assembly connector 5J1 (3). 2. Connect cable assembly (1) to adapter access plate connector (2). FOLLOW-THROUGH STEPS 1. Install smoke generator assembly on bracket (WP 0755 00). 2. Install inboard armor shield (WP 0771 00). 3. Connect battery ground strap (WP 0337 00). 4. Set circuit breaker CB1 to ON (TM 3-1040-283-10). END OF TASK 0761 00-3/4 blank