TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 549 of 928
TM 9-2350-277-20-5 REPLACE ADAPTER ACCESS PLATE TO GENERATOR ELECTRICAL CABLE ASSEMBLY (M1059A3 ONLY) 0761 00 THIS WORK PACKAGE COVERS: Removal (page 0761 00-1). Installation (page 0761 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0926 00, Item 65) P e r s o n n e l R e q u i r e d Signal Support System Specialist 31U10 R e f e r e n c e s See your -10 TM 3-1040-283-10 TM 3-1040-283-20&P E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Circuit breaker CB1 OFF (TM 3-1040-283-10) Battery ground strap disconnected (WP 0337 00) Air pressure released from compressor reservoir (TM 3-1040-283-20&P) Inboard armor shield removed (WP 0771 00) Smoke generator assembly removed from bracket (WP 0755 00) REMOVAL WARNING Before you do any maintenance, discharge all capacitors to ground or electrical shock could injure personnel. NOTE Left and right cable assemblies are replaced the same way. 1. Disconnect cable assembly (1) from adapter access plate connector (2). 0761 00-1