TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 548 of 928
TM 9-2350-277-20-5 REPLACE SMOKE GENERATOR INTERNAL CABLE ASSEMBLY (M1059A3 ONLY) — Continued 0760 00 4. Connect cable (1) to jack 1J3 (left) (10) or 1J4 (right) (11) on back of control panel (12). FOLLOW-THROUGH STEPS 1. Install smoke generator assembly on bracket (WP 0755 00). 2. Install inboard armor shield (WP 0771 00). 3. Connect battery ground strap (WP 0337 00). 4. Set circuit breaker CB1 to ON (TM 3-1040-283-10). END OF TASK 0760 00-4