TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 529 of 928

TM 9-2350-277-20-5 REPLACE SMOKE GENERATOR CONTROL PANEL ASSEMBLY (M1059A3 ONLY) — Continued 0756 00 4. Remove dust caps (3) from six connectors. 5. Connect fog oil pump cable assembly (1) to control panel assembly connector marked 1J5 (2). 6. Connect air compressor cable assembly (3) to control panel assembly connector marked 1J2 (4). 7. Connect smoke generator number 1 (right) cable assembly (5) to control panel assembly connector marked 1J3 (6). 8. Connect smoke generator number 2 (left) cable assembly (7) to control panel assembly connector marked 1J4 (8). 9. Connect main power cable assembly (9) to control panel assembly connector marked 1J1 (10). 0756 00-3