TM 9-2350-277-20-5 REPAIR PERSONNEL HEATER CONTROL BOX — Continued 0702 00 4. Remove HI-LO heat switch (16) from control box (13). a. Remove nut (14), lockwasher (15), instruction plate (if applicable), and HI-LO switch (16) from control box (13). Discard lockwasher. b. Remove two screws (17), lockwashers (18), jumper 13-20 (4), and lead 12-B (19) from HI-LO switch (16). 0702 00-3