TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download
Page 284 of 928
TM 9-2350-277-20-5 REPAIR PERSONNEL HEATER CONTROL BOX — Continued 0702 00 2. Remove indicator light assembly (19) from control box (12). a. Remove nut (8), lockwasher (9), and ground lead (10) from circuit breaker (7) mounting screw (11). Discard lockwasher. b. Remove screw (1), lockwasher (2), and lead 17-3 (5) from circuit breaker (7). c. Remove screw (13), lockwasher (14), and lead 19-2 (15) from RUN-OFF-START switch (16). d. Unscrew cap (17) and remove bulb (18) from light assembly (19). e. Remove nut (20), lockwasher (21), and light assembly (19) from control box (12). 3. Remove RUN-OFF-START switch (11) from control box (13). a. Remove six screws (1), lockwashers (2), jumper 15-17 (3), jumper 13-20 (4), lead 20-C (5), lead 14-A (6), jumper 21-18 (7), jumper 21-14 (8), lead 19-2 (9), and lead 19-E (10) from RUN-OFF-START switch (11). b. Remove two screws (12) and RUN-OFF-START switch (11) from control box (13). 0702 00-2