TM-9-2350-277-20-5 Unit Maintenance Manual Volume 5 M113A3 M577A3 M1064A3 M1068A3 M58 Download

Page 161 of 928

TM 9-2350-277-20-5 REPAIR HYDRAULIC RESERVOIR — Continued 0672 00 ASSEMBLY WARNING Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested. Do not service hydraulic system when FRH is hot or pressurized. Wear gloves and avoid contact with skin. If FRH contacts skin, wash immediately with soap. If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention. If FRH is swallowed, get medical attention. 1. Install filter (9) on adapter (8). 2. Install new preformed packing (10), filter (9), adapter (8), four new lockwashers (7), washers (6), and screws (5) in bottom of reservoir (11). 3. Install new preformed packing (4), elbow (3), tee (2), and two elbows (1) on side of reservoir (11). 0672 00-3